LED Lighting Retrofit Across Three Facilities Reduces Energy Consumption by 62% in Kitchener, Ontario

A coordinated LED lighting upgrade across three adjacent industrial automation facilities in Kitchener — delivering 220,447 kWh in combined annual savings and a 64.22 kW total demand reduction.

Hero — LED Lighting Retrofit Across Three Facilities Reduces Energy Consumption by 62% in Kitchener, Ontario
Completed December 18, 2018·86–90 Ardelt Ave., Kitchener, ON
The Challenge

Three legacy lighting generations failing in a cold-chain environment they were never specified for.

Brock Solutions operates three adjacent facilities on Ardelt Avenue in Kitchener, covering office, warehouse, and operational areas across the portfolio. Lighting represented a controllable electrical load at each location, but legacy systems were driving unnecessary consumption and peak demand across all three buildings.

Addressing the three facilities separately would have introduced coordination complexity and delayed the cumulative impact of the upgrade. The objective was to deliver a unified retrofit across the full portfolio in a single coordinated program, qualifying all sites for available incentives while minimizing disruption to ongoing operations.

The Solution

One sealed cold-rated fixture family across every zone, paired with zone-level occupancy logic.

Green Integrations completed LED lighting retrofits at all three Ardelt Avenue locations as part of a coordinated efficiency program, commissioned December 18, 2018.

Each facility received a full lighting system upgrade tailored to its specific layout and usage. Legacy lighting systems were replaced with high-efficiency LED fixtures selected to reduce electrical load while maintaining consistent illumination across office, warehouse, and operational areas.

All three sites qualified for incentives under the Save on Energy program. Green Integrations administered the documentation and submission process across the full portfolio to ensure compliance with program requirements.

Incentive program

The lighting upgrades qualified for incentives under the Save on Energy program. Incentive eligibility was determined based on verified reductions in energy consumption and electrical demand achieved at each facility. Green Integrations administered the documentation and submission process to ensure compliance with program requirements.

Results

The numbers, then the consequence.

December 18, 2018
Commercial operation
220,447kWh
Annual energy savings
63%
Energy reduction
64.22kW
Demand reduction
  • 01220,447 kWh in combined annual energy savings across all three facilities.
  • 0264.22 kW total demand reduction across the portfolio.
  • 03Average energy reduction of approximately 62% across all sites.
  • 04All three locations qualified for Save on Energy incentives in a single coordinated submission.
Environmental impact
14.0 tonnes CO₂e avoided each year.

Equivalent to removing 3 passenger vehicles from Ontario roads annually.

Standard environmental equivalency calculations
Technical summary

For the facilities and engineering audience.

Each of the three Ardelt Avenue facilities received a tailored lighting upgrade reflecting its specific layout, usage pattern, and electrical configuration. 90 Ardelt Avenue achieved the highest individual reduction at 73.8% energy reduction and 73.76% demand reduction. 86 and 88 Ardelt Avenue each achieved reductions in the 57–59% range, consistent with their facility types.

Total demand reduction across the portfolio was 64.22 kW — a meaningful reduction in the combined electrical footprint of all three sites. Incentive eligibility was determined based on verified reductions at each facility, with documentation managed centrally by Green Integrations.

Operational context

Facility characteristics that shaped the design.

  • Three adjacent industrial automation facilities covering office, warehouse, and operational areas
  • Legacy lighting contributing to unnecessary electricity consumption and peak demand across the portfolio
  • Coordinated multi-site retrofit delivered as a single program commissioned December 18, 2018
  • Upgrade executed without disruption to ongoing operations across all three facilities
  • Portfolio-level incentive qualification managed through a single Save on Energy submission
N E X T · S T E P
LED Lighting · Next step

Considering a lighting upgrade for your facility? A well-executed LED retrofit is one of the most consistent ways to reduce electrical demand and modernise building infrastructure.

What an assessment covers
  • ·Site photometric audit
  • ·Energy & demand baseline
  • ·Fixture and control specification
  • ·SaveON / IESO incentive stack
  • ·Phased installation plan